B&R X20BC0087 X20 Modbus TCP/UDP Bus Controller | 2xRJ45 Integrated Switch

B&R X20BC0087 X20 Modbus TCP/UDP Bus Controller | 2xRJ45 Integrated Switch

B&R X20BC0087 Modbus TCP/UDP slave bus controller for B&R X20 I/O system, dual RJ45 integrated Ethernet switch, 10/100 Mbit/s, DHCP & BootP support for industrial spare parts.
Send Inquiry
Products Introduction

Short Description

B&R X20BC0087 is a Modbus TCP / Modbus UDP slave bus controller for B&R X20 distributed I/O system. It is equipped with an integrated dual-port Ethernet switch with two RJ45 connectors, supporting 10/100 Mbit/s 10BASE-T/100BASE-TX communication, DHCP and BootP. It connects local X2X Link I/O stations to Modbus Ethernet networks, with configurable I/O cycle from 0.5 ms to 4 ms and response time from 1 ms to 8 ms. Featuring full module and bus diagnostics and front LED status indicators, it allows X20 I/O slices to communicate with third-party Modbus masters, widely used in industrial Ethernet retrofits, distributed I/O expansion and spare replacement.

Product Details

The B&R X20BC0087 belongs to B&R X20 Ethernet fieldbus bus controller family, designed as a Modbus TCP / Modbus UDP slave device. It bridges the X2X Link local backplane bus of X20 slice modules to standard Modbus Ethernet networks, enabling analog and digital I/O signals to be exchanged with any Modbus TCP/UDP master controller, including third-party PLC systems.

It integrates a built-in 2-port Ethernet switch with dual RJ45 ports, supporting daisy-chain wiring without extra external network switches. The physical layer supports 10BASE-T and 100BASE-TX auto-negotiation. The module supports DHCP and BootP for flexible IP address assignment. Users can configure the I/O cycle time between 0.5 ms and 4 ms to match application requirements, and the communication response time varies from less than 1 ms up to 8 ms depending on network load. It supports I/O configuration directly over the fieldbus and command sequence validity checking to improve system safety.

Electrical isolation is implemented between the Ethernet fieldbus, X2X Link backplane and I/O circuits to protect hardware from common-mode voltage and electrical transients. Built-in diagnostic functions continuously monitor module health and bus communication status. Front panel LED indicators display module operating status and bus activity, helping engineers quickly locate communication faults during commissioning and maintenance. This bus controller must be mounted on X20BB80 bus base, paired with X20PS9400 or X20PS9402 power supply module and X20TB12 terminal block.

This module holds CE, UKCA, cULus, ATEX Zone 2, HazLoc Class I Division 2, KC certifications, suitable for standard factory workshops and hazardous location applications. The compact slice housing supports power-off module replacement to minimize production downtime.

Typical applications include water treatment systems, packaging machinery, HVAC control, food processing and general factory automation. It is used for connecting X20 I/O stations to Modbus TCP networks, system expansion and spare maintenance of B&R X20 automation platforms.

Product Parameters

Model: X20BC0087Brand: B&R AutomationProduct Type: X20 Modbus TCP / Modbus UDP Slave Bus ControllerCompatible System: B&R X20 distributed I/O systemFieldbus Interface: Modbus TCP / Modbus UDP slave, 10BASE-T / 100BASE-TXPorts: 2 x RJ45, integrated dual-port Ethernet switchNetwork Features: DHCP, BootP, auto-negotiationI/O Cycle Time: Configurable 0.5 ms ~ 4 msResponse Time: <1 ms ~ 8 ms (depends on network load)Local Bus: X2X Link for X20 I/O slicesSecurity Function: Command sequence validity check before executionDiagnostic: Module status monitoring, bus communication diagnosticsIndicator: Front panel LED for module status and bus functionPower Consumption: 2 WRequired Accessories: X20BB80 bus base, X20PS9400 / X20PS9402 power supply, X20TB12 terminal blockCertifications: CE, UKCA, cULus, ATEX Zone 2, HazLoc Class I Division 2, KCProtection Class: IP20Operating Temperature: Horizontal: -25 ~ 60°C; Vertical: -25 ~ 50°CStorage / Transport Temperature: -40 ~ 85°CRelative Humidity: 5 ~ 95%, non-condensingMax Installation Altitude: 4000 m (temperature derating above 2000m)Software Support: B&R Automation StudioApplication: Modbus TCP distributed I/O connection, X2X Link to Modbus Ethernet gateway, third-party PLC I/O integration, industrial automation spare replacement


Tags: B&R X20BC0087 B&R X20 Modbus controller X20BC0087 bus controller B&R Modbus TCP I/O module