2324139713@qq.com

B&R X20CS1070 X20 CAN Bus Communication Interface Module

B&R X20CS1070 X20 CAN Bus Communication Interface Module

B&R X20CS1070 CAN bus interface module for B&R X20 I/O system, max 1 Mbit/s, CAN 2.0A/B, galvanic isolation, integrated termination resistor for CANopen device connection spare parts.
Send Inquiry
Products Introduction

Short Description

B&R X20CS1070 is a high-performance X20 series CAN bus communication interface module designed for B&R X20 distributed I/O automation system. It provides one CAN bus channel with maximum transfer rate up to 1 Mbit/s, equipped with transmit and receive object buffers for reliable CAN message handling. The CAN interface is galvanically isolated from the X2X Link backplane bus and I/O power supply to suppress electrical noise and common-mode interference. It integrates a built-in termination resistor and connects via X20TB12 12-pin terminal block, supporting a maximum cable length of 1000 meters. Front LED indicators display module operating status, bus activity, termination resistor status and fault alarms. It seamlessly integrates with X20 CPU and bus controller modules, widely used for CANopen device connection, machine networking and industrial spare replacement.

Product Details

The B&R X20CS1070 belongs to B&R X20 communication module family, which expands CAN bus fieldbus capability for the X20 automation station. It directly plugs into the X20 backplane and communicates with X20 CPU through X2X Link bus, enabling reliable connection with CAN and CANopen field devices such as drives, sensors, actuators and remote I/O modules.

The module adopts SJA1000 CAN controller with independent transmit and receive object buffers, optimizing message processing efficiency and reducing the load on the main PLC CPU. It supports CAN 2.0A and CAN 2.0B protocol standards. An integrated bus termination resistor can be activated as required, eliminating the need for external termination components at the bus end. The CAN channel features full galvanic isolation between the CAN field side and the X2X Link backplane plus I/O power circuit, protecting the X20 station from electrical surges, ground potential differences and field noise interference.

Wiring is completed via X20TB12 12-pin terminal block, which supports fast field wiring and convenient maintenance. The maximum CAN bus cable length reaches 1000 meters at 125 kbit/s baud rate; shorter cable length is required when running at higher baud rates up to 1 Mbit/s. Multi-status LED indicators on the front panel continuously monitor module running state, CAN bus data transfer activity, termination resistor activation status and module error conditions, helping engineers quickly locate communication faults during commissioning and routine maintenance.

This module supports DIN rail horizontal or vertical mounting inside IP20 control cabinets. It holds comprehensive global certifications including CE, UKCA, cULus, ATEX Zone 2, HazLoc Class I Division 2, DNV, ABS, LR, CCS, BV, KC and EAC. These approvals make it suitable for general factory automation, hazardous area applications and marine automation systems. It can work with all X20CP series CPU modules and X20 bus controllers to add CAN fieldbus networking without replacing the main control hardware.

Typical applications include packaging machinery, CNC equipment, plastic injection machines, textile machines, material handling lines and marine control systems. It serves as CAN bus expansion interface, CANopen device gateway and spare maintenance component for B&R X20 automation platforms.

Product Parameters

Model: X20CS1070Brand: B&R AutomationProduct Type: X20 CAN Bus Communication Interface ModuleCompatible System: B&R X20 distributed I/O systemInterface: 1 x CAN busCAN Controller: SJA1000Protocol: CAN 2.0A, CAN 2.0BMax Transfer Rate: 1 Mbit/sObject Buffer: Transmit and receive object bufferBuilt-in Termination Resistor: YesMax Cable Length: 1000 m (125 kbit/s)Connection Terminal: X20TB12 12-pin terminal blockIsolation: CAN channel galvanically isolated from X2X Link bus and I/O power supplyPower Consumption: Bus:0.01 W; Internal I/O:1.44 WDiagnostic Indicators: Front LED for operating state, data transfer, termination resistor status, module errorMounting: DIN rail mount, horizontal / vertical installationOperating Temperature: Horizontal: -25 ~ 60°C; Vertical: -25 ~ 50°CStorage / Transport Temperature: -40 ~ 85°CRelative Humidity: 5 ~ 95%, non-condensingMax Installation Altitude: 4000 m (temperature derating above 2000m)Certifications: CE, UKCA, cULus, ATEX Zone 2, HazLoc Class I Division 2, DNV, ABS, LR, CCS, BV, KC, EACProtection Class: IP20Software Support: B&R Automation StudioApplication: CANopen device networking, CAN bus field communication expansion, machine automation retrofit, industrial automation spare replacement


Tags: B&R X20CS1070 B&R X20 CAN bus module X20CS1070 communication module B&R CANopen interface

Reliance Electric 57407 AutoMa

Reliance Electric 57406 AutoMa

Reliance Electric 57405 AutoMa

Reliance Electric 57402 115V A

Leave Your Message


Leave a message