2324139713@qq.com

Bently Nevada 90200-03-01-02-02-01-01-02 Dual RTD Temperature Monitor Module

Bently Nevada 90200-03-01-02-02-01-01-02 Dual RTD Temperature Monitor Module

Bently Nevada 90200-03-01-02-02-01-01-02 dual-channel RTD temperature monitor module, collects Pt100 sensor signals for bearing and casing temperature monitoring and over-temperature protection of rotating machinery.
Send Inquiry
Products Introduction

Content Introduction

The Bently Nevada 90200-03-01-02-02-01-01-02 is a dual-channel RTD temperature monitor module for rotating machinery online condition monitoring systems. It receives resistance signals from Pt100 RTD temperature sensors to measure bearing metal temperature and casing temperature. It can set independent alarm limits for each channel and trigger warning signals when temperature exceeds thresholds, providing over-temperature protection for compressors, pumps, fans and motors in power, oil & gas and petrochemical industries.

Details

This dual RTD monitor supports two separate RTD input channels for simultaneous temperature measurement. It features built-in sensor diagnostics to detect probe open circuit and short circuit faults, avoiding false readings caused by damaged sensors or broken wiring. It adopts rack mount structure for installation in Bently Nevada monitoring racks. Each channel can be configured independently for alarm and trip parameters. It delivers stable temperature data for machine health assessment and predictive maintenance. This customized model supports special range and output configuration defined by the full model code. It is widely used for new system assembly and spare replacement of industrial machine monitoring projects.

Product Parameters

Model: 90200-03-01-02-02-01-01-02 Brand: Bently Nevada Product Type: Dual Channel RTD Temperature Monitor Module Number of Channels: 2 independent input channels Supported Sensor: Pt100 RTD temperature probe Measurement: Bearing and casing temperature monitoring Diagnostics: RTD open circuit and short circuit fault detection Mounting: Rack mount Operating Temperature: -30°C to +65°C Humidity: 95% non-condensing Function: Temperature reading, alarm threshold configuration, fault diagnosis Compliance: CE Application: Rotating machinery temperature monitoring and over-temperature protection


Tags: Bently Nevada 90200 90200-03-01-02-02-01-01-02 dual RTD monitor module temperature monitoring unit

Reliance Electric 57410 Analog

Reliance Electric 57407 AutoMa

Reliance Electric 57406 AutoMa

Reliance Electric 57405 AutoMa

Leave Your Message