2324139713@qq.com

GE SR745-W3-P5-G5-HI Multilin 745 Three-Winding Transformer Management Relay

GE SR745-W3-P5-G5-HI Multilin 745 Three-Winding Transformer Management Relay

GE SR745-W3-P5-G5-HI is Multilin SR745 three-winding transformer management relay with 5A CT input, high-density I/O and wide-range auxiliary power, providing percentage differential, REF and V/Hz overexcitation protection for three-winding power transformers and autotransformers in power plants, supporting communication with Mark V turbine control system.
Send Inquiry
Products Introduction

Content Introduction

The GE SR745-W3-P5-G5-HI belongs to GE Multilin SR745 series high-speed multi-processor transformer management relay. Model decoding: W3 = three-winding transformer configuration; P5 = 5A phase CT secondary input; G5 = high-density I/O group; HI = wide-range auxiliary power supply. It integrates percentage differential protection, backup protection, electrical metering, OLTC tap monitoring, COMTRADE fault recording and FlexLogic programmable logic, mainly applied for three-winding power transformers, autotransformers and shunt reactors in power plants and substations. Widely used in combined-cycle power plant main three-winding transformers and station service transformers, capable of uploading transformer measurement data, trip signals and fault alarms to Mark V turbine control system and plant DCS/SCADA. SR745 series is EOL legacy protection IED, spare parts are mostly refurbished units for power substation maintenance and retrofit.

Details

SR745-W3-P5-G5-HI adopts draw-out pluggable chassis, front LCD display and keypad, front RS232 local programming port; parameter commissioning and real-time data viewing via EnerVista setup software. Core protection functions: 87T dual-slope percentage differential protection with 2nd/5th harmonic inrush restraint, restricted earth fault (REF), phase overcurrent (50/51), neutral ground overcurrent (50N/51N), negative sequence overcurrent (46), V/Hz overexcitation protection, thermal overload protection, over/under voltage, over/under frequency, OLTC tap supervision, CT saturation detection. Measurement & monitoring: three-phase voltage/current, active/reactive/apparent power, power factor, frequency, winding temperature, tap position, harmonic distortion monitoring, breaker operation counter. Logic & I/O: FlexLogic™ programmable logic engine, 16 programmable binary inputs, 8 relay trip/alarm outputs, multi RTD temperature input channels. Data recording: high-precision Sequence of Events (SOE), COMTRADE fault oscillography, 4 groups of setting groups, setting modification audit trail, transformer thermal trend log for post-fault analysis. Communication interfaces: front RS232, rear RS485/RS422; optional Ethernet module. Supports Modbus RTU/TCP, DNP3.0, IEC60870-5-103, IRIG-B time synchronization. PCB can be coated with conformal coating option, suitable for power plant cabinet environment with dust, oil mist and condensation. It cooperates with Mark V turbine control system to transmit transformer alarm and measurement signals to plant DCS.

Product Parameters

Model: SR745-W3-P5-G5-HI Brand: GE Multilin / GE Vernova Series: SR745 Transformer Management Relay Transformer type: Three-winding transformer / autotransformer CT secondary input: 5A phase CT Auxiliary control power(HI):70~265VAC / 90~300VDC,48~62Hz I/O allocation:16 binary inputs,8 relay outputs, multi RTD inputs Display: Front LCD with keypad Communication: Front RS232, rear RS485/RS422, optional Ethernet; Modbus RTU/TCP, DNP3.0, IEC103, IRIG-B Mounting: Panel mount, draw-out chassis Operating temperature: -20℃ ~ +60℃ Humidity:5%~95% non-condensing PCB treatment: Optional conformal coating Diagnostics: Power-on self-test, SOE event log, COMTRADE fault waveform capture, 4 setting groups, audit trail Application: Combined-cycle power plant three-winding main transformer and station service transformer primary protection, OLTC tap monitoring, interconnection with Mark V turbine control system, substation power transformer integrated protection and fault recording


Tags: SR745 transformer management relay GE 745 differential protection relay GE SR745-W3-P5-G5-HI Multilin SR745 three-winding transformer relay Mark V main transformer protection

Reliance Electric 57407 AutoMa

Reliance Electric 57406 AutoMa

Reliance Electric 57405 AutoMa

Reliance Electric 57402 115V A

Leave Your Message


Leave a message