Products Introduction

Short Description
ICS TRIPLEX 9852 is a high-reliability digital output termination assembly designed for TMR safety instrumented systems with SIL3 certification. It provides isolated 24VDC output channels for emergency shutdown and safety interlock control in critical process industries.

Product Details
The ICS TRIPLEX 9852 belongs to the ICS TRIPLEX trusted safety control series. It works with T9451 digital output modules and compatible backplane units to form a complete safety output channel. It adopts triple modular redundant architecture with built-in channel diagnostic and circuit monitoring functions to detect open circuit, short circuit and load faults in real time. Each channel supports 24VDC output with 2A rated current, and it provides electrical isolation between field loads and internal control circuits. The model 9852 features 8 dual redundant output channels; direct interchange with other termination assemblies requires bench performance testing and compatibility verification. Common faults include fuse burnout, terminal corrosion and internal circuit damage. Technicians can perform channel forced test and health diagnosis via the safety system configuration software. This ICS TRIPLEX 9852 is original industrial spare part, available for new supply and repair exchange. It complies with CE, ATEX and IECEx certifications.
Typical applications include ESD emergency shutdown system, burner management system, pipeline safety interlock, chemical reactor protection and power plant safety control projects.

Product Parameters
Model: 9852Brand: ICS TRIPLEXProduct Type: Digital Output Termination Assembly, TMR Safety AccessoryArchitecture: Triple Modular Redundancy (TMR)Safety Grade: SIL3Channel: 8 dual redundant 24VDC output channelsOutput Rating: 24VDC, 2A per channelPower Supply: 24VDC, dual redundant power input with independent fuse protectionIsolation: Galvanic isolation between field side and control sideWorking Temperature: -40°C ~ +70°CStorage Temperature: -40°C ~ +85°CHumidity: 5% ~ 95% RH, non-condensingQuality Check: Continuity test, isolation test, full channel diagnostic test before shipmentProduct Status: Original new / overhaul availableCertifications: CE, ATEX, IECExApplication: Oil & gas industry, chemical processing, power generation, safety instrumented system, emergency shutdown system

Tags: ICS TRIPLEX 9852 9852 ICS termination assembly ICS TRIPLEX digital output module TMR safety termination board SIL3 SIS spare parts