Products Introduction
Product Brief
The NI cFP-SG-140 is an 8-channel strain and bridge input module for Compact FieldPoint systems. It supports half-bridge and full-bridge strain gauge measurement with selectable excitation voltage, widely used as spare parts for legacy industrial stress and load monitoring systems.

Product Details
The NI cFP-SG-140 installs on Compact FieldPoint backplanes and provides eight differential input channels for strain gauge and bridge sensor measurement. It supports both half-bridge and full-bridge configurations, with programmable bridge completion function for flexible sensor wiring.
It features 16-bit delta-sigma ADC and three selectable excitation voltages: 2.5 V, 5 V and 10 V. Four measurement ranges are available: ±3.90625 mV/V, ±7.8125 mV/V, ±31.25 mV/V and ±62.5 mV/V. Built-in noise filters of 15 Hz, 60 Hz and 240 Hz help suppress power-line interference for stable readings.
It supports hot swap and auto-configuration. Technicians can replace the module without shutting down the whole I/O bank. It has 2300 Vrms transient isolation protection to defend against surge voltage in factory environments. Onboard diagnostics detect overcurrent and out-of-range faults, with channel LEDs for quick fault identification.
Measurement setup, calibration and data reading can be operated through LabVIEW, NI MAX and FieldPoint OPC Server.
This is an end-of-life legacy NI module. It only works with Compact FieldPoint platform and compatible drivers. It is mainly stocked for maintenance of existing test and monitoring nodes. New projects generally choose CompactRIO C-series strain measurement modules.
Rugged industrial design fits DIN rail cabinet mounting. Typical applications include load cell testing, structural stress measurement and force transducer acquisition.
Product Parameters
Part Number: cFP-SG-140
Brand: National Instruments (NI)
Channel Count: 8 differential strain gauge input channels
Resolution: 16-bit, delta-sigma ADC
Bridge Type: Half-bridge, full-bridge
Excitation Voltage: 2.5 V, 5 V, 10 V programmable
Measurement Ranges: ±3.90625 mV/V, ±7.8125 mV/V, ±31.25 mV/V, ±62.5 mV/V
Noise Filter Options: 15 Hz, 60 Hz, 240 Hz
Isolation Rating: 2300 Vrms transient withstand
Feature: Hot swappable, auto-configuration, onboard diagnostic
Mounting: Install on Compact FieldPoint backplane
Compatible Platform: All Compact FieldPoint backplanes and controllers
Supported Software: LabVIEW, NI MAX, FieldPoint OPC Server
Product Status: End of Life (EOL)
Typical Application: Strain gauge measurement, load cell and force sensor acquisition, legacy FieldPoint spare replacement
Tags: NI cFP-SG-140 cFP-SG-140 module Compact FieldPoint strain gauge NI bridge input module