The NI PCI-6230 is a legacy bank-isolated M Series multifunction data acquisition board designed for PCI-based industrial measurement and noisy test environments. It provides 8 analog input channels, bank-isolated digital I/O and dual 32-bit counter-timers. Built-in bank isolation effectively eliminates ground loop interference, together with NI-MCal self-calibration, programmable voltage ranges and digital trigger function. It is widely stocked as spare hardware for industrial sensor monitoring, field signal logging, factory automation test and legacy test bench maintenance.

Product Details
The NI PCI-6230 is a 32-bit 33 MHz PCI DAQ card from NI isolated M Series family. It can be configured as 8 single-ended or 4 differential analog input channels with 16-bit ADC resolution, with maximum aggregate sampling rate of 250 kS/s.
This version has no analog output channels. It features 4 bank-isolated 5 V TTL/CMOS digital I/O lines. Two independent 32-bit counter-timers with 80 MHz timebase support edge counting, frequency measurement, pulse width measurement and quadrature encoder reading.
The onboard NI-MCal self-calibration circuit ensures stable measurement accuracy over long operation periods. It adopts a 37-pin D-SUB connector and requires isolated rated shielded cables to meet full specification. It only works with NI-DAQmx driver and supports programming via LabVIEW, LabWindows/CVI and C/C++.
This is an end-of-life National Instruments DAQ device. New industrial isolated measurement applications can select newer PCIe isolated DAQ hardware as alternatives.
Typical applications include noisy industrial site signal collection, ground-loop prone sensor measurement, static multi-point logging and legacy industrial measurement system retrofit.

Product Parameters
Part Number: PCI-6230, 779615-01
Brand: National Instruments (NI)
Bus Interface: PCI 32-bit, 33 MHz
ADC Resolution: 16-bit
Analog Input Channels: 8 single-ended / 4 differential AI
Analog Output Channels: None
Max Aggregate Sampling Rate: 250 kS/s
Input Voltage Range: ±10 V
Digital I/O: 4 bank-isolated TTL lines, 5 V TTL/CMOS
Counter / Timer: 2 x 32-bit counter, 80 MHz timebase
Isolation Type: Bank isolation
Calibration: NI-MCal onboard self-calibration supported
Trigger Mode: Digital trigger supported
Connector: 37-pin D-SUB connector
Supported Driver: NI-DAQmx
Compatible Software: LabVIEW, LabWindows/CVI, C/C++
Product Status: End of Life (EOL)
Typical Application: Isolated industrial signal acquisition, ground loop suppression test, legacy M Series PCI DAQ spare replacement
Tags: 250kS/s multifunction data acquisition NI PCI-6230 PCI-6230 DAQ isolated M Series DAQ