Products Introduction

Content Introduction
The NI PCI-6601 is a legacy high-performance counter-timer PCI board from the NI 660x series. It features four independent 32-bit up/down counter channels and up to 32 TTL-compatible digital I/O lines, supporting pulse generation, event counting, period measurement, frequency measurement and encoder position tracking. It includes built-in digital debounce and glitch removal functions, plus RTSI bus synchronization for coordinated timing operations with other NI DAQ boards. It is widely stocked as spare hardware for pulse timing control, quadrature encoder reading, frequency monitoring and legacy test bench automation maintenance.

Product Details
The NI PCI-6601 is a 32-bit PCI timing and measurement instrument with four 32-bit counters. The maximum input frequency is 20 MHz directly, and up to 60 MHz when using the onboard prescaler. It works with 5 V TTL/CMOS logic signals.
It supports buffered counter operations and one DMA channel for high-speed event logging. The internal timebases include 20 MHz and 100 kHz reference clocks with ±50 ppm stability. Digital debounce filtering eliminates noise and contact bounce on input signals. The RTSI bus connector enables trigger and clock sharing across multiple PCI DAQ cards for multi-board synchronization.
This board uses a 68-pin SCSI-II connector and is compatible with NI shielded cables and SCB-68 terminal blocks. It supports both NI-DAQmx and Traditional NI-DAQ legacy drivers and can be programmed with LabVIEW, LabWindows/CVI and C/C++.
This is an end-of-life National Instruments counter/timer device. New timing and encoder applications can select modern PCIe counter-timer modules as alternatives.
Typical applications include quadrature encoder position measurement, pulse output generation, frequency and period measurement, event counting, motion trigger synchronization and legacy timing system retrofit.

Product Parameters
Part Number: PCI-6601, 777918-01
Brand: National Instruments (NI)
Bus Interface: PCI 32-bit
Counter Channels: 4 independent 32-bit up/down counters
Digital I/O Lines: Up to 32 TTL/CMOS compatible lines
Direct Max Input Frequency: 20 MHz
Max Input Frequency with Prescaler: 60 MHz
Internal Timebases: 20 MHz, 100 kHz
Clock Stability: ±50 ppm
Logic Level: 5 V TTL / CMOS
Special Functions: Pulse generation, frequency measurement, period measurement, encoder measurement, digital debounce filter, RTSI synchronization, DMA transfer
Operating Temperature: 0 °C to 55 °C
Humidity Range: 10% to 90% non-condensing
Connector: 68-pin SCSI-II connector
Supported Driver: NI-DAQmx, Traditional NI-DAQ (Legacy)
Compatible Software: LabVIEW, LabWindows/CVI, C/C++
Product Status: End of Life (EOL)
Typical Application: Counter timer measurement, quadrature encoder monitoring, pulse and frequency test, legacy 660x timing board spare replacement
Tags: NI PCI-6601 PCI-6601 counter timer card 4 channel 32-bit counter PCI encoder measurement board