The NI PXI-2559 is a dual terminated SPDT RF relay switch module designed for PXI broadcast, CATV and video automated test systems. It contains two independent single-pole double-throw channels with built-in 75 Ω termination resistors, 75 Ω characteristic impedance and 2.5 GHz bandwidth, optimized for video RF signal routing and stimulus-response test setups. Built with latching electromechanical relays, it features low insertion loss, excellent VSWR and high channel isolation, equipped with onboard relay cycle counter and PXI hardware trigger synchronization. It is widely used together with other 75 Ω RF switching modules and stocked as spare replacement hardware.

Product Details
The NI PXI-2559 is a single-slot 3U PXI RF switch module based on latching electromechanical relay architecture.
Each SPDT port is internally terminated with 75 Ω resistors to suppress unwanted RF reflections and protect signal sources.
Front-panel Mini SMB female connectors provide stable 75 Ω RF interconnection and match NI Mini SMB series shielded RF cables.
Insertion loss and phase offset calibration data can be stored and compensated inside NI Switch Executive to reduce measurement uncertainty.
The built-in relay cycle counter continuously logs switching cycles for relay wear monitoring and predictive maintenance.
PXI trigger bus enables synchronous channel switching aligned with RF instrument sampling sequences to improve test throughput.
It runs under NI-SWITCH driver and supports programming via LabVIEW, NI Switch Executive, LabWindows/CVI and C/C++.
This is an end-of-life National Instruments RF relay switch module.
Typical applications include broadcast video signal routing, CATV tuner validation, custom 75 Ω RF switching network construction and legacy PXI-2559 switch spare replacement.
Product Parameters
Part Number: PXI-2559
Brand: National Instruments (NI)
Form Factor: 3U PXI, single slot
Topology: Dual terminated SPDT, two independent SPDT relay channels
Switch Type: Latching electromechanical relay (EMR)
Nominal Impedance: 75 Ω
Max Bandwidth: 2.5 GHz
Max Switching Voltage: 30 V
Max Switching Current: 0.5 A per channel
Max RF Power: 10 W channel-to-common
Termination Power Rating: 1.5 W at ≤25 °C
DC Path Resistance: <0.35 Ω initial, ≤1.0 Ω at end of life
Connector Interface: Mini SMB female connectors
Onboard Function: Relay cycle count monitoring, RF calibration data storage support
Synchronization: PXI trigger bus support
Driver: NI-SWITCH
Compatible Software: LabVIEW, NI Switch Executive, LabWindows/CVI, C/C++
Operating Temperature: 0 °C to 55 °C
Product Status: End of Life (EOL)
Typical Application: Broadcast and CATV ATE signal routing, 75 Ω video RF parametric automated test system
Tags: NI PXI-2559 PXI-2559 RF switch 2.5GHz 75 ohm dual terminated SPDT PXI CATV video RF relay module