ProSoft MVI46-PDPMV1 SLC 500 PROFIBUS DP-V1 Master Communication Module

ProSoft MVI46-PDPMV1 SLC 500 PROFIBUS DP-V1 Master Communication Module

Buy ProSoft MVI46-PDPMV1 module, connect Rockwell SLC 500 PLC to PROFIBUS DP-V0/DP-V1 slave devices for industrial fieldbus control.
Send Inquiry
Products Introduction

Content Introduction

The ProSoft MVI46-PDPMV1 is a single-slot PROFIBUS DP-V1 master module for Rockwell SLC 500 1746 backplane. It enables SLC processors to connect to PROFIBUS DP networks and exchange cyclic I/O as well as acyclic parameter data with DP-V0 and DP-V1 slave devices, including drives, remote I/O, transmitters and field instruments. It is widely used in petrochemical, water treatment, power distribution and legacy SLC automation upgrade projects. It serves as a reliable spare replacement unit for PROFIBUS fieldbus integration.

Product Details

This ProSoft MVI46-PDPMV1 module installs directly into the 1746 SLC local or extended rack backplane. It complies with IEC 61158 PROFIBUS DP master standard, supporting Class 1 and Class 2 DPV1 acyclic services for device parameter reading and diagnostics. PROFIBUS data is mapped to SLC M0 and M1 register files for ladder logic access.

It is equipped with a DB9 PROFIBUS interface and a dedicated RS232 configuration port for setup and diagnostics. Configuration is completed via ProSoft Configuration Builder software. Front panel LED indicators display module status, backplane communication, PROFIBUS bus activity and fault alarms for fast on-site troubleshooting. Powered by the SLC backplane, no separate 24V DC power supply is required. It is an ideal solution for integrating SLC 500 PLCs into existing PROFIBUS DP-V1 networks.

Product Parameters


ParameterSpecification
ModelMVI46-PDPMV1
SeriesMVI46 SLC 500 In-Chassis PROFIBUS Module
Continuous stall torque-
Continuous stall current-
Peak current-
Rated power4.2 W
Max speedPROFIBUS up to 12 Mbps
Max voltageBackplane powered
Insulation class-
Protection classIP20
Feedback typeSLC 1746 backplane, PROFIBUS DP-V1 Master
Shaft-
MountingSLC 1746 chassis mounting
Ambient temperature range0°C to 60°C
Relative humidity5% to 95%, non-condensing
WeightRefer to manufacturer datasheet