ProSoft PLX32-MBTCP-PND Modbus TCP to PROFINET IO Device Dual Subnet Gateway

ProSoft PLX32-MBTCP-PND Modbus TCP to PROFINET IO Device Dual Subnet Gateway

Buy ProSoft PLX32-MBTCP-PND gateway, dual isolated Ethernet port bidirectional converter connecting Modbus TCP field devices to Siemens PROFINET controllers.
Send Inquiry
Products Introduction

Content Introduction

The ProSoft PLX32-MBTCP-PND is a dual electrically isolated subnet industrial protocol gateway functioning as a PROFINET IO Class A device. It supports bidirectional real-time data exchange between Modbus TCP/IP networks and PROFINET controllers. It connects Siemens PROFINET PLCs with Modbus TCP power meters, variable frequency drives, flow transmitters, remote I/O modules and SCADA hosts. The dual independent Ethernet ports separate Modbus TCP and PROFINET networks without modifying the original IP address scheme of existing devices. It is widely used in factory automation, water treatment, energy monitoring and production line retrofit projects. It is a reliable spare part for integrating Modbus TCP field devices into PROFINET control systems.

Product Details

This DIN-rail mounted gateway is equipped with two isolated 10/100 Mbps Ethernet ports for independent subnets. It is certified to PROFINET V2 Class A standard, supporting cyclic PROFINET RT real-time I/O and acyclic parameter access, with up to 1440 bytes input and 1440 bytes output data capacity. It supports multiple simultaneous Modbus TCP client and server connections, and up to 10,000 16-bit registers for large-volume data mapping.

It is configured via ProSoft Configuration Builder software. An SD card slot is reserved for configuration backup and quick replacement for fast device commissioning. It supports remote network diagnosis and ProSoft Discovery Service for convenient IP assignment. Conformal coating is optional for harsh industrial environments. It holds UL/cUL Class I Division 2, ATEX Zone 2 and CE certifications. Front panel LEDs indicate power, fault status and communication activity of each Ethernet port.

Product Parameters


ParameterSpecification
ModelPLX32-MBTCP-PND
SeriesPLX32 Dual-Port Isolated PROFINET Gateway
Rated Power24 VDC nominal, 10–36 VDC wide range
Interface2×10/100M Isolated Ethernet
Power SupplyExternal 10–36 VDC
Protection ClassIP20
CommunicationModbus TCP/IP, PROFINET IO Class A Device (RT)
MountingDIN rail mounting
Operating Temperature-25°C to 70°C
Relative Humidity5% to 95%, non-condensing
WeightRefer to manufacturer datasheet