Products Introduction

Content Introduction
The NI PXI-8532 is a single-port DeviceNet industrial fieldbus communication module developed by National Instruments for PXI and CompactPCI test and automation systems. Built on the CAN physical layer, it supports DeviceNet master/scanner and slave node functions, and is widely used in factory automation equipment testing, material handling systems, assembly line control, industrial sensor and actuator verification, and spare replacement for existing DeviceNet-based test platforms.

Product Details
The NI PXI-8532 is designed for DeviceNet industrial bus communication, different from the NI-XNET automotive bus series modules. It works with the NI-Industrial Communications for DeviceNet driver, allowing users to configure the module as a master scanner to manage multiple slave nodes on the DeviceNet network, or set it as a slave device for communication simulation and validation. It adopts dedicated onboard hardware processing to handle bus scheduling, I/O data exchange and message parsing independently, which reduces host CPU load and ensures stable cyclic data transmission for industrial automation tasks.
This module supports standard DeviceNet baud rates including 125 kbps, 250 kbps and 500 kbps, and complies with the DeviceNet protocol specification managed by OVDA. It uses a DB-9 D-Sub connector following standard DeviceNet pin definition, which supports bus power supply and signal wiring for direct connection with standard DeviceNet cables and network terminators. It can synchronize timing with other PXI instruments through the PXI trigger bus, which is convenient for building integrated test systems combining data acquisition, motion control and fieldbus communication.
Users can develop and debug DeviceNet applications via LabVIEW, LabWindows/CVI, NI MAX and related industrial communication APIs. It supports both Windows and LabVIEW Real-Time operating systems, suitable for offline equipment verification and continuous online production monitoring. It adopts standard 3U single-slot PXI form factor and draws power from the PXI backplane. As a classic industrial fieldbus interface, it is commonly stocked as replacement hardware for legacy DeviceNet automation test benches.
Product Parameters
Communication Protocol: DeviceNet (based on CAN physical layer)
Channel Count: 1 port
Supported Baud Rates: 125 kbps, 250 kbps, 500 kbps
Operating Mode: Master / Scanner, Slave
Connector Type: DB-9 D-Sub (DeviceNet standard pinout)
Form Factor: 3U PXI single slot
Power Supply: Powered from PXI backplane
Operating Temperature: 0 ℃ to 55 ℃
Storage Temperature: -20 ℃ to 70 ℃
Operating Humidity: 10% to 90% non-condensing
Supported Driver: NI-Industrial Communications for DeviceNet
Supported Software: LabVIEW, LabWindows/CVI, NI MAX, Real-Time OS
Compatible Systems: PXI, CompactPCI chassis
Tags: NI PXI-8532 DeviceNet PXI interface module industrial fieldbus communication card National Instruments DeviceNet scanner module